Low temperature and humidity sensor for refrigerator and freezer / Model number M906EN-010AW

Measurement range: Temperature -40℃ to +70℃, Humidity 0% RH to 100% RH, Transmission interval 10 minutes.

Measurement range: Temperature -40℃ to +70℃, Humidity 0% RH to 100% RH Transmission interval: 10 minutes Powered by lithium battery with a lifespan of about 5 years even in dark conditions Simple waterproof type EnOcean communication (928.35MHz 1mW) Ideal for low-temperature environments such as refrigerators - can be used at -40℃ Compact size of business card Battery life: approximately 5 years

  • Thermo-hygrometer

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Low temperature and humidity sensor for refrigerator and freezer / M906EJ-010AW

Low-temperature temperature and humidity sensor for refrigerator and freezer.

■Operation Mode This product is equipped with a mode to switch the "transmission state" to reduce battery consumption when not in use. Please switch to the "stop state" before storing the product during transportation or when it is not in use. - Switching from "stop state" to "transmission state" Bring a magnet close to the magnetic detection part to turn ON, and move it away to turn OFF, using the following method for switching: ON for 5 seconds (Teach-in transmission) → OFF for 1 second or more but less than 10 seconds → ON for 5 seconds (Teach-in transmission and output transmission) - Switching from "transmission state" to "stop state" ON for 10 seconds or more (Teach-in transmission and output transmission while ON, and re-send Teach-in transmission after 10 seconds) → OFF (Teach-in transmission) In the "transmission state," when turned ON, it sends a Teach-in transmission and immediately sends an output once. After that, it sends an output once every specified time interval.